Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
reference:instrumentation:openlogger:start [2019/01/09 14:19]
Arthur Brown [Documentation]
reference:instrumentation:openlogger:start [2019/10/18 15:38] (current)
Arthur Brown
Line 1: Line 1:
-<WRAP center round todo 60%> 
-OpenLogger coming soon! Please check out the [[https://​www.crowdsupply.com/​digilent/​openlogger|Crowd Supply page]] for more details on the OpenLogger. 
-</​WRAP>​ 
- 
 ~~NOTOC~~  ​ ~~NOTOC~~  ​
 ====== OpenLogger ====== ​ ====== OpenLogger ====== ​
   ​   ​
 {{Digilent Infobox {{Digilent Infobox
-| Store Page = TBD+| Store Page = https://​store.digilentinc.com/​openlogger-high-resolution-portable-data-logger/​
 | Getting Started = getting-started | Getting Started = getting-started
 | Manual = [[reference-manual]] | Manual = [[reference-manual]]
Line 14: Line 10:
 | Subtitle = Wireless data logging and data acquisition device | Subtitle = Wireless data logging and data acquisition device
    
-| Header = Design Resources 
-| Pinout Printout = {{:​reference:​instrumentation:​openlogger:​openlogger-mz-pinout.png|OpenLogger Pinout}} 
-| FAQ = [[reference/​instrumentation/​openlogger/​faq | FAQ and Known Issues]] 
- 
 | Header = Connectivity | Header = Connectivity
 | Bullet = Wifi (802.11g) | Bullet = Wifi (802.11g)
Line 25: Line 17:
 | Channels = 8 | Channels = 8
 | Resolution = 16-bit | Resolution = 16-bit
-| Sample Rate = 400 kS/s+| ENOB = 12-bit 
 +| Sample Rate = 500 kS/s
 | Bandwidth =  50 kHz | Bandwidth =  50 kHz
 | Input Impedance = 1 MΩ | Input Impedance = 1 MΩ
Line 31: Line 24:
 | Max Buffer Size = 32640 Samples per channel | Max Buffer Size = 32640 Samples per channel
  
-| Header = Arbitrary Waveform ​Generator+| Header = Function ​Generator
 | Channels = 1 | Channels = 1
 | Resolution = 10-bit | Resolution = 10-bit
-| Sample Rate = 10 MS/s+| Sample Rate = MS/s
 | Bandwidth = 1 MHz at -3dB | Bandwidth = 1 MHz at -3dB
 | Voltage Range = 3V peak-to-peak ±1.5V offset. | Voltage Range = 3V peak-to-peak ±1.5V offset.
Line 48: Line 41:
  
 | Header = Misc | Header = Misc
-| Bullet = PIC32MZ2064DAG169 microcontroller 
-| Bullet = 2 External Trigger Lines 
 | Bullet = USB powered device (B Micro) | Bullet = USB powered device (B Micro)
 | Bullet = Accepts external power between 5.5 and 17 V | Bullet = Accepts external power between 5.5 and 17 V
-| Bullet = 4 user LEDs+| Bullet = 4 indicator ​LEDs
  
 | Header = Software | Header = Software
 | WaveForms Live = [[/​reference/​software/​waveforms-live/​start | WaveForms Live]] | WaveForms Live = [[/​reference/​software/​waveforms-live/​start | WaveForms Live]]
 +| Supported Browsers = Chrome, Safari, and Firefox
 | Digilent Agent = [[/​reference/​software/​digilent-agent/​start | Digilent Agent]] | Digilent Agent = [[/​reference/​software/​digilent-agent/​start | Digilent Agent]]
 +| Supported OSs = Windows Only
  
 | Header = Firmware | Header = Firmware
-| Without Bootloader = {{|none available yet}} +| Without Bootloader = {{https://s3-us-west-2.amazonaws.com/digilent/Software/​OpenLogger+MZ/​release/​firmware/​without-bootloader/​OpenLoggerMZ-1.3.0.hex|Hex file without bootloader}}
-| With Bootloader = {{|none available yet}} +
-| Source = [[https://github.com/Digilent/openlogger | GitHub link (not available yet)]] +
-| Bullet = [[previous-versions ​Previous Versions]]+
  
 | Header = Pinout | Header = Pinout
Line 71: Line 61:
 | GND = Digital Ground | GND = Digital Ground
 | 5V = 5V Supply | 5V = 5V Supply
-| AWG = Arbitrary Waveform ​Generator+| AWG = Function ​Generator ​Output
 | DC1 = DC Out 1 | DC1 = DC Out 1
 | DC2 = DC Out 2 | DC2 = DC Out 2
Line 79: Line 69:
 | Tout = Reserved | Tout = Reserved
  
 +| Header = Design Resources
 +| Pinout Printout = {{:​reference:​instrumentation:​openlogger:​openlogger-mz-pinout.png|OpenLogger Pinout}}
 }} }}
  
Line 101: Line 93:
 ---- ----
  
-/* 
 ===== Example Projects ===== ===== Example Projects =====
 +
 {{topic>​openlogger +project}} {{topic>​openlogger +project}}
 +
 ---- ----
-*/ 
  
 /* /*
Line 112: Line 104:
 */ */
  
-===== Additional Resources ​=====+===== Accessories ​=====
  
-  ​* [[/reference/software/digilent-instrumentation-protocol/​start]]+**OpenLogger Screw Terminal Adapter**: Purchase through the [[https://www.crowdsupply.com/digilent/​openlogger|OpenLogger Crowd Supply Campaign]]. Additional information can be found in the Screw Terminal Adapter'​s [[screw-terminal-adapter-reference-manual|Reference Manual]]
 + 
 +===== Additional Resources =====
   * [[reference/​software/​waveforms-live/​start|WaveForms Live Resource Center]]   * [[reference/​software/​waveforms-live/​start|WaveForms Live Resource Center]]
   * [[reference/​software/​digilent-agent/​start|Digilent Agent Resource Center]]   * [[reference/​software/​digilent-agent/​start|Digilent Agent Resource Center]]
 +  * [[/​reference/​software/​digilent-instrumentation-protocol/​start]]
   * [[reference/​instrumentation/​openlogger/​recover-from-corrupt-firmware]]   * [[reference/​instrumentation/​openlogger/​recover-from-corrupt-firmware]]
 +  * [[reference/​software/​waveforms-live/​how-to-convert-dlog]]
   * [[https://​www.microchip.com/​wwwproducts/​en/​ATWINC1500|ATWINC1500 Wifi Radio Certifications]]   * [[https://​www.microchip.com/​wwwproducts/​en/​ATWINC1500|ATWINC1500 Wifi Radio Certifications]]
  
 == Downloads == == Downloads ==
  
 +  * [[/​reference/​instrumentation/​openlogger/​case-assembly-manual]]
   * [[/​reference/​instrumentation/​openlogger/​acrylic-case-files]]   * [[/​reference/​instrumentation/​openlogger/​acrylic-case-files]]
   * [[/​reference/​instrumentation/​openlogger/​schematic]]   * [[/​reference/​instrumentation/​openlogger/​schematic]]
-  * [[/reference/instrumentation/openlogger/​pcb-dimensions]]+  * {{ :reference:instrumentation:openlogger:​openlogger_mz_dimensions.jpg?​linkonly | OpenLogger PCB Dimensions}}
  
 ---- ----