 ====== OpenLogger - Calibration ====== ====== OpenLogger - Calibration ======
 +
 +===== First-Time Calibration =====
  
 Before being used for the first time, a new OpenLogger must first be calibrated. This process determines constants used to accurately calculate analog voltages for data points being logged, and stores these constants in non-volatile memory. Before being used for the first time, a new OpenLogger must first be calibrated. This process determines constants used to accurately calculate analog voltages for data points being logged, and stores these constants in non-volatile memory.
 +
 +**Note:** //After first-time calibration, described in this guide, a device can be recalibrated, if desired, through its Configuration Menu, found through the Device Manager in WaveForms Live.//
  
 ---- ----
Line 10: Line 14:
 When the device is connected to WaveForms Live for the first time, a prompt to calibrate the OpenLogger will appear. Click **OK**. When the device is connected to WaveForms Live for the first time, a prompt to calibrate the OpenLogger will appear. Click **OK**.
  
-**Note:** //After first-time calibration, a device can be recalibrated, if desired, by clicking the CALIBRATE button in its configuration screen.// 
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
Line 21: Line 24:
 === 2. === === 2. ===
 Connect the provided 2x18 flywires to the OpenLogger with the nub side facing towards the center of the OpenLogger. Connect the provided 2x18 flywires to the OpenLogger with the nub side facing towards the center of the OpenLogger.
 +----
 === 3. === === 3. ===
 Connect the red wire on pin 6 (DC OUTPUT 1) to the solid orange wire on pin 35 (Analog Input 1). Take a look at the [[:reference:instrumentation:openlogger:reference-manual#openlogger_pinout|OpenLogger Pinout]] in the Reference Manual for details on which wire corresponds to which OpenLogger pin. Connect the red wire on pin 6 (DC OUTPUT 1) to the solid orange wire on pin 35 (Analog Input 1). Take a look at the [[:reference:instrumentation:openlogger:reference-manual#openlogger_pinout|OpenLogger Pinout]] in the Reference Manual for details on which wire corresponds to which OpenLogger pin.
Line 27: Line 30:
 <WRAP column half> <WRAP column half>
 {{ https://reference.digilentinc.com/_media/learn/instrumentation/tutorials/openlogger/calib-1.png?500 |Connect the red and orange wires}} {{ https://reference.digilentinc.com/_media/learn/instrumentation/tutorials/openlogger/calib-1.png?500 |Connect the red and orange wires}}
 +
 </WRAP> </WRAP>
 </WRAP> </WRAP>
Line 66: Line 70:
 <WRAP column half> <WRAP column half>
 === 8. === === 8. ===
-A final calibration complete screen will appear. Click the **DONE** button. +A final calibration complete screen will appear. Click the **DONE** button - see the image to the right
-</WRAP> +----
-<WRAP column half> +
-{{ :reference:instrumentation:openlogger:calibration_complete.png?500 |Calibration complete}} +
-</WRAP> +
-</WRAP> +
- +
-<WRAP group> +
-<WRAP column half>+
 === 9. === === 9. ===
 Click the **DONE** button at the bottom of the page to back out to the configuration screen. Click the **DONE** button at the bottom of the page to back out to the configuration screen.
 +----
 +=== 10. ===
 +In the device configuration screen, click the back arrow at the top left of the page to return to the device selection screen.
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ :reference:instrumentation:openlogger:initial_instrument_panel.png?500 |Initial Instrument Panel}}+{{ :reference:instrumentation:openlogger:calibration_complete.png?500 |Calibration complete}}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
  
-<WRAP group> +---- 
-<WRAP column half> +===== More Information ===== 
-=== 10. === + 
-In the device configuration screenclick the back arrow at the top left of the page to return to the device selection screen. +Check out the OpenLogger's [[reference:instrumentation:openlogger:start|Resource Center]] for more guidestutorials, and projects.
-</WRAP> +
-</WRAP>+
  
 {{tag>openlogger}} {{tag>openlogger}}
 {{include_n>4}} {{include_n>4}}